Your winter low here averages 27°F, and about 160 nights a year sit at or below freezing. That matters because a standard heat pump starts falling short of its rated heat output below 40°F, and often needs backup heat below about 35°F. Your average night is colder than both marks. So on more than half the nights between October and May, a standard heat pump is not putting out full heat on its own.
That doesn't mean it stops working. It means it needs help, usually electric resistance coils, to carry the house the rest of the way. The running-cost figures on this page don't include that backup heat, because they're built from the heat pump's rated seasonal efficiency alone. On a 27°F night here, the real cost of running a standard heat pump is higher than the $2.00 figure above.
There's a version built for this. A heat pump with the ENERGY STAR Cold Climate mark has to prove, under third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F, and keeps at least 70 percent of its warm-weather capacity at that temperature. Field tests of prototype cold-climate units found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even down to 0°F. Your 0°F nights here are rare too, about 3 a year. A cold climate model is built for nights like your coldest, not your average one, and your average one is already past where a standard unit struggles.