What the cold here does to a heat pump
Winter is the long season here. Heat runs October through May, eight months, against two months of cooling in July and August. Whatever you pick is mostly a heating decision, because it has eight months to prove itself and only two to make up for it.
The average overnight low across December, January and February is 25°F. That is below both marks that matter for a standard heat pump. Below 40°F it stops putting out its full rated heat. Below about 35°F it often needs backup heat to make up the difference. Twenty-five is under both, not close to either.
This is not a rare cold snap. Of the roughly 245 nights heat runs here, about 150 drop to freezing or below, more than half the season. A standard heat pump is working below its rating on most of the nights you need it most.
It does not mean the heat pump fails. It means a standard one leans on backup heat, usually electric resistance, for a good part of the winter, and that backup heat costs more to run than the heat pump itself. A heat pump built to the ENERGY STAR Cold Climate spec is a different machine: it has to hold at least 70 percent of its rated output and still produce 1.75 units of heat per unit of electricity at 5°F, tested by someone other than the manufacturer. That is the spec built for a winter like this one, not the federal minimum.
The deep cold itself is rare. Nights at 0°F or below come about once a year here. A field test of prototype cold-climate heat pumps found backup heat covered only a small share of the output between 0°F and 35°F, and the units almost never ran on backup alone above 0°F. The hard case, if you buy the right machine, barely comes up.