Electricity here runs 15 cents a kilowatt-hour
Nevada homes paid 15.00 cents per kilowatthour in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on, winter or summer.

Takes about a minute. No obligation.
Nevada homes paid 15.00 cents per kilowatthour in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on, winter or summer.
Two heat pumps rated differently will show it on your bill at this rate. The one you pick for Lovelock is going to run on this same power cost for as long as it's in the ground.

NOAA nClimDiv, 1991–2020 normals
Heat here runs October through May, eight months out of the year.
Get a heat pump installed before September and it's broken in and running right by the time you need it.




Pershing County sits in climate zone 5B, a cool zone where heating carries more of the load than cooling does. Any split-system heat pump installed new here, as of January 2023, has to hit 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. Those are federal floors, not local extras, so every qualifying unit on the market already clears them. A federal tax credit is available on top of that for equipment that qualifies, which is worth asking a contractor about when you're comparing models. The zone sets the minimum. What you choose above that minimum is what shows up on your power bill every month you run it.
At 15 cents a kilowatt-hour, the efficiency rating on the unit you install is what decides your bill, not just this winter but every winter after. That makes the choice worth getting right before it goes in the ground.
Find a contractor
Whatever gets pulled out was sized for a house and a set of habits that existed when it went in. Rooms get finished, windows get swapped, and nobody redoes the math after. A contractor sizing the replacement should run that math fresh instead of matching the old tonnage. The outdoor unit being removed has sat through every storm and every season since installation, and the coil has been collecting dirt the whole time in a way no filter catches. If it's a straight heat pump swap, the line set and pad usually stay as they are. Coming off a furnace or boiler means more changes, since a heat pump moves air differently and needs ductwork built for that.
Sizing a heat pump right means measuring the house itself. Wall and ceiling insulation, window area, air leakage, how each room sits against the weather. That math produces a heating and cooling load. The equipment gets matched to that load, not picked by a rule of thumb or matched to whatever size came out of the ground.
A heat pump too big for the load satisfies the thermostat fast and shuts off before it has pulled moisture out of the air or warmed the place evenly. Rooms far from the thermostat stay cold or clammy. One too small runs constantly during the coldest and hottest stretches and still can't keep up. Either way it cycles more than it should, and a heat pump wears best when it gets to settle into a long, steady run.
What you pay for an installation comes down to what the job actually requires, not just the equipment sitting on the truck. A straight swap, same spot, same line set, same ductwork, is the cheapest version of this job because the hard parts are already done. Add a new circuit for the outdoor unit, or ductwork sized for a heat pump instead of a furnace, and the labor grows before the equipment is even unboxed. The unit itself varies too. A higher efficiency rating usually costs more up front, and a variable-speed compressor costs more than a single-stage one, because there's more built into it to control output. Site conditions matter as well. A pad that needs leveling, a line set that has to run further than before, electrical panel work if the existing panel can't take the new load, all of that gets priced separately from the heat pump itself. None of it shows up in a quote that only lists the equipment.
Install day starts with the old equipment coming out. That takes longer than people expect once the line set and refrigerant are involved. The refrigerant gets recovered before anything is disconnected, never vented into the air. With the old unit gone, the pad gets set or leveled, the line set gets run or reused, and the new outdoor unit gets placed and secured. Indoors, the air handler or coil goes in, and the electrical connections get made, including a dedicated circuit sized for the new equipment. Once everything is connected, the system gets charged with refrigerant to the exact weight the manufacturer specifies, not by feel. The part that gets skipped when a job is rushed comes last. Airflow gets measured at the registers, and the system gets run through a full cycle to check that every room is actually getting what the thermostat thinks it's getting.