Electricity here runs 15 cents a kilowatt-hour
Nevada homes paid that rate in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies every month, not just in summer.

Takes about a minute. No obligation.
Nevada homes paid that rate in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies every month, not just in summer.
Two heat pumps can heat and cool the same house and use different amounts of power to do it. At this rate, the difference between them is worth checking before you decide, not after.

NOAA nClimDiv, 1991–2020 normals
Utility gas heats 55 percent of homes in Churchill County, more than any other fuel.
A heat pump replacing a gas furnace changes the fuel your heat runs on, so the switch is worth understanding before you install.



Winter nights here average 22 degrees, cold enough to run a heat pump but not the kind of extreme that pushes a system to its limit for months on end. Churchill County gets hit by damaging wind more than winter storms, 51 events against 10 over the last decade, and wind is harder on a roof or a fence than on equipment sitting in a yard or on a pad. A heat pump built for this climate doesn't need to be the highest-efficiency unit on the lot to hold up. It needs to be sized right for the house and installed well. Put the money into a good installation rather than a model built for harsher winters than this one sees.
Any heat pump installed here now has to meet 14.3 SEER2 and 7.5 HSPF2 at minimum, so the low end of the market already clears that bar. In the Southwest, a central air conditioner has to hit that same 14.3 SEER2 too. That narrows what a contractor can put in, and a federal tax credit is available on top of it.
Find a contractor
A heat pump that's too big cools the house fast and shuts off before it pulls the moisture out of the air, so the house feels clammy even at the temperature you set. It also cycles on and off more, and every start wears the compressor a little. One that's too small runs flat out on the coldest and hottest days and still can't keep up, so it leans on backup heat strips that burn far more power than the compressor does. Getting it right starts with a room-by-room load calculation, not the size of the unit it's replacing. That math looks at the square footage, the windows, the insulation, and the direction the house faces, and it sizes the equipment to the house as it actually is now.
A furnace or straight air conditioner has to come out before the heat pump goes in, and if the furnace runs on gas, that line gets capped off by someone licensed to do it. The ductwork usually stays, but a contractor should check it against what the new system needs before assuming it carries over as is.
If the system being replaced is a central air conditioner, the refrigerant in its lines can't be vented into the air. It has to be recovered by the contractor before the lines are disconnected. That's part of the removal, not an extra step tacked on after.
That SEER2 and HSPF2 number on the label is a ratio, not a promise. It compares the heat moved against the power it took to move it, tested under set conditions, so it tells you how units stack up against each other more than what either one will actually do in your house. A higher rated unit is more efficient at turning electricity into heat or cooling, but the house it's attached to still decides the real result. Poor duct sealing or a system sized wrong will eat into that rating no matter what's printed on the label. The rating is a starting point for comparing equipment, not a guarantee of what shows up on a bill.
Installation day starts with the outdoor unit and the indoor coil, not the thermostat on the wall. The old equipment comes out first, lines get disconnected and capped, and the pad or mounting bracket for the new outdoor unit gets set and leveled before anything goes on it. Line sets usually get replaced rather than reused, since the refrigerant in a heat pump system has to move freely through clean copper with no old oil or debris left behind. Once the new coil and air handler or furnace are in place, the lines get connected, pressure tested, then pulled into a vacuum to clear out moisture and air before refrigerant ever goes in. Electrical is its own piece of the job, since a heat pump draws differently than straight AC and the disconnect, breaker and wiring get checked against what the new unit calls for. Only after all that gets closed up does a contractor charge the system, run it in both heating and cooling, and check the temperatures coming off the coil against what the manufacturer specs.