Electricity here runs 15 cents a kilowatt-hour
Nevada homes paid about 15.00 cents per kilowatt-hour in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on, all year.

Takes about a minute. No obligation.
Nevada homes paid about 15.00 cents per kilowatt-hour in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on, all year.
Two heat pumps can heat and cool the same house and use different amounts of electricity to do it. At this rate per kilowatt-hour, the difference between an efficient unit and a weak one shows up on every bill, not just a few.

NOAA nClimDiv, 1991–2020 normals
The old system comes out once the new one is set and running.
If it's a straight swap, the house isn't without heat or cooling while the work gets done.




Elko County falls in climate zone 5B, a cool, dry zone where the heating load matters more than cooling. Any split-system heat pump installed here has to meet the federal minimum of 7.5 HSPF2 for heating and 14.3 SEER2 for cooling, since those standards took effect for units built from January 2023 on. That sets a floor on what a contractor can install, not a ceiling. A system can be rated well above those minimums, and in a zone where heating runs most of the year, the heating rating is worth asking about as much as the cooling one. Installing a qualifying heat pump can also qualify a homeowner for the federal energy efficiency tax credit.
At 15 cents a kilowatt-hour, the HSPF2 and SEER2 ratings on the unit going in are worth settling now, not after it's installed. Ask what each option is rated at before deciding.
Find a contractorA heat pump that's too big cycles on, satisfies the thermostat fast, and shuts off again before it's pulled the moisture out of the air or settled the temperature room to room. One that's too small runs constantly in the coldest stretch and never quite catches up. Either way the compressor is doing more starts and stops than it should, and that wear adds up over the years it's expected to last. Sizing isn't a guess off the old unit's rating plate. A contractor works it out with a load calculation, room by room, using the square footage, the windows, the insulation, and which way the house faces the weather. Houses that look alike from the street can need different sized systems depending on what's actually in the walls and how much glass faces the sun. Done right, the number that comes out of that calculation is what gets installed, not the next size up for peace of mind.
If the ducts already in the house are sized right and sealed well, a contractor can connect the new heat pump and move on. If they're leaky, crushed, or too small for what the new system needs to push through, that gets fixed first. A heat pump can only deliver the air the ducts are able to carry.
The outdoor unit needs clearance on all sides and a line set run back to the indoor coil. A straight run to a spot close to the electrical panel is simple. A longer run, a tight crawlspace, or a panel that needs upgrading to handle the new unit's electrical load all add steps before the system can be set and charged.
Comparing quotes only works if the quotes are for the same thing. Ask what capacity each contractor is proposing and whether it came from a load calculation or from matching the unit that's already there. Ask what HSPF2 and SEER2 the proposed equipment carries, not just the brand name, since models from the same manufacturer can sit far apart on both ratings. Ask whether the quote includes fixing the ductwork or just hooking into what's already run. Ask about the line set and what it takes to reach the spot picked for the outdoor unit, and whether the electrical panel can handle the new load as it sits or needs work first. The cheapest number and the right number aren't always the same one, and the only way to tell is to ask what's actually included.
The crew starts outside, setting the new unit on its pad and running the line set to where the indoor coil goes. Inside, the old air handler or coil comes out only once the new equipment is ready to take over, so a straight swap doesn't leave the house sitting without heat or cooling. Once everything's connected, the system gets charged with refrigerant and run through both modes before anyone signs off. That means checking airflow at the registers, confirming the thermostat is actually controlling the unit, and measuring static pressure in the ducts. A heat pump fighting the wrong duct resistance will run harder than its rating suggests, no matter how correctly it was sized. If the ductwork needs rework beyond a simple connection, that gets handled as its own step, and it's worth asking upfront how that part of the job is scheduled.